Hydraulic Sealant 35A72 100ml - Arexons 4732

ArexonsSKU: 305_023_AR4732

Price:
Sale price€21,53
Availability : 36

Description

Hydraulic Sealant 35A72 100ml - Arexons 4732

Specific product for sealing all fittings in general up to a diameter of 2".

Removal is possible with normal tools. High thixotropy product.

The high thixotropy prevents the treated surfaces from dripping and allows application without waste.

Contains PTFE, which exerts a lubricating action during assembly, thus ensuring perfect tightening of threaded parts.

Ensures a perfect seal against liquids and gases. Protects threads against corrosion and prevents loosening caused by vibration.

Withstands most industrial products.

It is recommended for couplings with a max. diametral play of 0.3 mm.

For best results, the product should be applied if both threads are to be joined.

The anaerobic characteristic, i.e. the fluid state in the presence of air, allows easy removal of excess product.

Employment

Recommended for sealing threaded joints and fittings in general, pipes and vessels containing gas, LPG, compressed air, oil and fuels, industrial fluids, CFCs, drinking water and various chemicals.

Classification

Product tested according to DIN 54454

Approved as sealant for gas-tight fittings according to EN751-1 by DIN-DVGW

No. NG-5146AR0574 -20°C to +150°C up to 2" diameter

Use

Before assembly, clean and dry the threads (water, oil or dirt will not guarantee adhesion of the sealant to the threaded parts).

Warnings

This product is not normally recommended for use with plastics, where stress cracking is possible. 

Storage

Product shelf life after packaging in sealed package and storage at room temperature: 18 months minimum.

Technical specifications

Base Resina metacrilica anaerobica
Colour Bianco crema
Specific weight 1,01 g/ml
Viscosity at 25°C 17000 - 70000 mPa.s
Maximum diametrical play 0,30 mm
Maximum thread diameter M80 - 2”

Unscrewing resistance (N.m)

initial

residual

6 – 11

2 – 5

Creep resistance (N/mm2 ) 4 - 6

Curing time

manipulation

functional

finale

 

20 – 40 minutes

1 – 3 Hours

24 Hours

Operating temperature -55°C +150°C

Chemical resistance: Test carried out after 24 hours of curing the product at the indicated temperature.

Substance °C Resistance after 100 h Resistance after 1000 h Resistance after 5000 h
Engine oil 125 discreet discreet discreet
Gearbox oil 125 discreet discreet discreet
Petrol 25 excellent excellent excellent
Water/glycol 50% 87 excellent good poor
Brake fluid 25 excellent excellent excellent